Stop construction dust before it damages your critical IT.

ProtectIT is our proven system for protecting live IT environments during refurbishment or retrofit – enclosure, HEPA-filtered pressure control and validated air-quality reporting.

During refurbishment or retrofit, one of the greatest — and most underestimated — threats to your data centre or server room is construction dust. These microscopic particles are abrasive, conductive and highly damaging to fans, circuit boards and power supplies.

Refurbishment work produces vast quantities of fine particulate contamination. Contractors rarely understand how sub-micron particles behave; even careful isolation lets dust bypass makeshift barriers and spread through positive-pressure airflow into data halls.

Plaster dust is particularly dangerous. Its critical relative humidity is lower than the environment in most data centres, so it absorbs moisture from the air, becomes damp, and drives corrosion (sulphur and copper creep), ionic migration and permanent electronic damage.

THE HIDDEN THREAT
Four steps to a  protected IT environment.

STEP 01

Enclose the zone

Specialist containment isolates either the live IT equipment or the construction work area.

STEP 02

HEPA-filtered pressure

0.3μm air scrubbers create positive pressure over IT (keeping dust out) or negative pressure over works (trapping dust in).

STEP 03

Prove & certify

Real-time air-quality and temperature monitoring keeps the environment stable and safe throughout the project.

STEP 04

Reassemble & reinstall

Air particulate readings in both zones prove the system worked. Post-works clean and ISO 14644-1:2015 Class 8 certification hand the room back audit-ready.

Trained and experienced on complex systems including Quantum Scalar Tape Libraries. Heavily contaminated equipment can be safely cleaned and restored without voiding manufacturer warranties.

Proven across the UK

ProtectIT has safeguarded large enterprise data halls, high-density server rooms and sensitive communications/control rooms — including a large tape library at a UK university, kept fully operational while a comms-room wall was removed. To date, no contamination of the protected IT equipment has occurred.

Managed containment

We can supply a contamination-control manager on-site — running airlock doors, providing HEPA-filtered vacuums for contractors, monitoring particulate levels, maintaining pressures and air scrubbers, and holding temperature. After the works we clean, take proving air-particulate readings against ISO 14644-1 Class 8 (3,520,000 particles at 0.5μm), then remove the enclosure and hand the room back.

Ready to protect your critical IT infrastructure?

Speak to a specialist today. We’ll provide a no-obligation quote, tailored to your environment and operational requirements.

Call us

0844 5555 171

Email Us

sales@itcleaning.co.uk

Coverage

Nationwide - United Kingdom

Contact Us
error: Content is protected !!

Before You Leave

Reduce Dust, Prevent Overheating, Improve Uptime — Get Your Data Centre Cleaned by Experts.